UK/IEUSER MANUALWALL HUNG RSF GAS FIRED CONDENSING SYSTEM BOILERGREENSTAR i SYSTEM6720643356-00.1WoFOR CENTRAL HEATING SYSTEMS6 720 644 864a (2010/10)
10CONTROLS6 720 644 864a (2010/10)3.1.4 BOILER RESETIn the event of a fault, the reset button will flash once per second and the blue mains indicator
11SYSTEM PRESSURE6 720 644 864a (2010/10)4SYSTEM PRESSURE4.1 SEALED HEATING SYSTEMSThis boiler is fitted to a sealed heating system which is pre-press
12SYSTEM PRESSURE6 720 644 864a (2010/10)4.2 EXTERNAL FILLING LOOPOnce the external filling loop has been located, follow the instructions for re-pres
13SERVICE CLEARANCES6 720 644 864a (2010/10)5 SERVICE CLEARANCESYour installer will have provided adequate space around the boiler for safety and serv
14MAINTAINING YOUR BOILER6 720 644 864a (2010/10)6 MAINTAINING YOUR BOILERYour new gas-fired boiler represents a long term investment in a reliable, h
15FAULT FINDING6 720 644 864a (2010/10)7FAULT FINDINGIf a boiler fault occurs, please read the following page thoroughly before contacting Worcester,
16FAULT FINDING6 720 644 864a (2010/10)EXTREME COLD WEATHERIn instances where the condensate pipe work is run external or in an unheated area, such as
17FAULT OR BREAKDOWN6 720 644 864a (2010/10)8 FAULT OR BREAKDOWNThis boiler is supported in the UK and Eire by Worcester, Bosch Group.Specialist Servi
18TIPS ON ENERGY SAVING6 720 644 864a (2010/10)9 TIPS ON ENERGY SAVINGHEATING ECONOMICALLYThe boiler provides a high level of comfort whilst keeping g
19TIPS ON ENERGY SAVING6 720 644 864a (2010/10)DRAUGHTSTry to ensure that draughts around doors, windows, letterboxes and keyholes etc. arereduced by
2PREFACE6 720 644 864a (2010/10)PREFACEPLEASE READ THESE INSTRUCTIONS CAREFULLYThese instructions are applicable to the Worcester, Bosch Group boiler
20ENVIRONMENT / DISPOSAL6 720 644 864a (2010/10)10 ENVIRONMENT / DISPOSALEnvironmental protection is a fundamental corporate strategy of the Bosch Gro
21YOUR GUARANTEE6 720 644 864a (2010/10)11 YOUR GUARANTEEThis boiler is guaranteed against faulty materials or workmanship for a period of 2 years fro
22GLOSSARY6 720 644 864a (2010/10)12 GLOSSARYCentral heating systemsAll radiators must be heated at an even rate. If the top of a radiator is at a low
23GLOSSARY6 720 644 864a (2010/10)
WORCESTER, BOSCH GROUP:TECHNICAL SUPPORT: 0844 892 3366APPOINTMENTS: 0844 892 3000SPARES: 01905 752571LITERATURE: 0844 892 9800TRAINING: 01905 752526S
3CONTENTS6 720 644 864a (2010/10)CONTENTS1 Symbols and safety precautions . . . . . . . . . . . . . . . 41.1 Explanation of symbols . . . . . . . . .
4SYMBOLS AND SAFETY PRECAUTIONS6 720 644 864a (2010/10)1 SYMBOLS AND SAFETY PRECAUTIONS1.1 EXPLANATION OF SYMBOLSWARNING SYMBOLSSignal words indicate
5SYMBOLS AND SAFETY PRECAUTIONS6 720 644 864a (2010/10)1.2 SAFETY PRECAUTIONSIF YOU SMELL GAS!B Call the National Gas Emergency Service on: 0800 111 9
6GENERAL INFORMATION6 720 644 864a (2010/10)2 GENERAL INFORMATIONSERVICINGB The boiler must be serviced regularly by a competent, qualified person, su
7CONTROLS6 720 644 864a (2010/10)3CONTROLSB To gain access to the boiler controls push the top centre of the flap and release.Fig. 1 Control panel fas
8CONTROLS6 720 644 864a (2010/10)3.1 OPERATING THE BOILERSETTING THE CENTRAL HEATING TEMPERATURE1. Turn the central heating temperature control knob t
9CONTROLS6 720 644 864a (2010/10)3.1.2 BOILER FROST PROTECTIONIf the temperature within the boiler falls below 8°C the pump will run to circulate wate
Comentários a estes Manuais