SYSTEM PRESSURE
6 720 802 048 (2013/05)
4.4 OPTIONAL INTEGRAL KEYED FILLING LINK
Locate filling key and follow instructions for re-pressurising.
1. Push the filling key firmly into the body of the filling link, ensuring the arrow on the key shaft lines up with the open padlock
symbol.
2. Turn the filling key to the right, to the stop, so the arrow now lines up with the closed padlock symbol. This bridges the gap
between the two sections of the filling loop.
3. Turn the white knob to the left, this will allow water to fill the system.
4. When the pressure, shown on the boiler fascia pressure gauge, reaches between the 1 and 1.5 bar marks (zone A), turn the white
knob to the right to close the valve. Do not overtighten.
5. Turn the filling key to the left, to the stop, so that the arrow lines up with the open padlock symbol and pull the key straight down
to remove. Please remember to store the key in the bottom panel.
Fig. 10 Keyed filling link
3.
2.
1.
6720643356-10.3Wo
4.
5.
2
3
1
04
bar
1
A
Min
1 bar
1.5 bar
Max