3.3 TECHNICAL DATA
3.4 RELATED STANDARDS:
BS EN60730-1:2001 + A2:2008
BS EN60730-2-7:1992
Electro Magnetic Compatibility (EMC) and
Radio Spectrum Matters (ERM); Short Range
Devices (SRD) ETSI EN 300 220-1
3.5 EC DIRECTIVES:
European Union Law Directive (2000/84/EC)
Low Voltage Directive (2006/95/EC)
Electro Magnetic Compatibility Directive
(2004/108/EC)
CE Marking Directive (93/68/EEC)
Description Units Transmitter Receiver
Dimensions mm H158 x W75 x D36.5
Operating voltage V 2 x AA/LR6 Batteries 24V d.c.
Ambient Operating Temperature °C -5 to +45 -5 to +45
Class of protection II II
Degree of protection IP 20 20
Accuracy sec/day ±2.5 @ 25°C
Battery life years 1 approx.
Shortest switching period minutes 15
Temperature regulation range °C +5 to +30
Regulator Electronic
Transistor switching capacity mA 5mA @ 24V d.c.
Switching contact Open collector
Tab. 5 Technical data