Worcester Wave Manual de Serviço Página 11

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 32
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 10
11
Compatibility
Gas-fired boilers Oil-fired boilers
COMBI
SYSTEM
^
REGULAR*
COMBI SYSTEM REGULAR
CDi Classic
2
CDi Compact
Si Compact
Greenstar i
Highflow CDi
CDi Classic
System
27i System and
30i System
9i – 24i System
27Ri and 30Ri
Heatslave II
Heatslave II
External
Danesmoor
System
Danesmoor
Comfort controls Part no.
Comfort 7 733 600 003
D
1
DD
2
DDD
1
DD
2
DD
3
Comfort I RF 7 733 600 001
D
1
DD
2
DDD
1
DD
2
D DD
3
Comfort II RF 7 733 600 002
D
1
DD
2
DDD
1
DD
2
D DD
3
*With optional wiring centre (see page 23).
^With optional integral diverter valve.
1
Manufactured after 16th January 2007 with software version CF12.10 onwards.
2
Manufactured after February 2011.
3
Should be used with Comfort wall plate kit (7 733 600 039) to allow the plug-in programmer or RF receiver to be wall
mounted and hard-wired to the boiler.
Correct at time of printing. For the latest list of compatible boilers see the Worcester website.
Technical data – Comfort range
Controller model Comfort Comfort I RF Comfort II RF
Height
110mm 110mm 111mm
Width
133mm 133mm 134mm
RF
U
DD
Load compensation
U
DD
Rated current
2-wire BUS 2-wire BUS 2-wire BUS
Control range
N/A
4 - 30ºC
in steps of 0.1ºC
4 - 30ºC
in steps of 0.1ºC
Permissible ambient
temperature
0 - 60°C 0 - 60°C 0 - 60°C
Protection level
1PX2D
1PX2D
(fascia mounted)
IP20 (wall mounted)
IP20
Control position
Fascia mounted
Programmer
fascia mounted/
Thermostat
wall mounted
Wall mounted
ErP class with compatible
Greenstar gas-fired boilers
–VV
System efficiency benefit with
Greenstar gas-fired boilers
3% 3%
ErP class with compatible
Greenstar oil-fired boilers
–I I
System efficiency benefit with
Greenstar oil-fired boilers
+1% +1%
Vista de página 10